Back to Home Page

 


TC331/MC331/MC330

Tank Requirements
Inspection Form

 


Company Name:______________________   Date:___________________
Inspected By:_________________________ Truck #:__________ Tank Serial #:_____________


Item

Date of
Tank
Certification

Requirements

X
Metal I.D. Plate All Permanently attached to the tank or its supporting
structure on the left or right (can be either
depending on year of construction) side near the
front
 
Stamping on I.D. Plate All The identification plate must be stamped
with either:
TC331  
MC331  
MC330  
(V) External Visual Inspection (M1) All Once per year (Three years from the last test But no
later than Aug 15, 2003)
 
(K) Leakage Test (M1) All Once per year (First test no later than Aug 15, 2003)  
(I) Internal Visual Inspection (M5) All Once every 5 Years (First test no later than Aug 15,
2003 if never performed in accordance to Standard-
contact registered facility who performed last
pressure test - M5 inspection)
 
(P) Pressure Test (M5) All Once every 5 Years  
Liquid and Vapour Discharge
Openings Less Than 1 1/4" NPT
All Must be equipped with an excess flow valve and a
manually operated external valve (approved ball
valve)
 
Liquid and Vapour Discharge
Openings of 1 1/4" NPT
Before Oct
1/84
Must be equipped with an excess flow valve and a
manually operated external valve (approved ball
valve) or internal shut-off valve (ISC valve)
 
Liquid and Vapour Discharge
Openings 1 1/4" NPT or Larger
Between Oct
1/84 and Aug
15/02
Must be equipped with a remotely controlled internal
shut-off valve (ISC valve or FlomaticŪ)
 
Liquid and Vapour Line and each
Filling and Discharge Line for Liquid
New Unit
After Aug
15/02
Must be equipped with a remotely controlled self-
closing valve (ISC valve or FlomaticŪ with remote
cable control or pheumatic control shut-down)
 
Engine Fuel Line Not Over 3/4" NPT All Must be equipped with an excess flow valve  

Tanks 3501 USWGC and Larger

All

Must be equipped with two means of automatic
closure installed outside the cab at the ends of the
tank in diagonally opposing locations
 

Tanks 3500 USWGC and Less

All

Must be equipped with a means of automatic closure
installed outside the cab at one end of the tank,
away from the discharge connection area
 


This document is a "Guide Only", and is not a comprehensive checklist for truck inspections. Please refer to
"B620/98 or 87" for complete requirements.


All tank inlets and outlets, except safety relief valves, shall be marked to designate whether they communicate
with vapour or liquid when the tank is filled to the maximum permitted filling density. For example: a spray fill
connection is considered a vapour valve because it communicates with the vapour space of the tank.

 

Your One Stop Tank Shop!

 